How to Read this Report
This report is organized by the property's functional areas.
Within each functional area, descriptive information is listed first and shown
in bold type. Items of concern follow descriptive information and are shown as
follows:
|
|
Safety |
Poses a risk of injury or death |
|
|
Major defect |
Correction likely involves a significant expense |
|
|
Repair/Replace |
Recommend repairing or replacing |
|
|
Repair/Maintain |
Recommend repair and/or maintenance |
|
|
Minor defect |
Correction likely involves only a minor expense |
|
|
Maintain |
Recommend ongoing maintenance |
|
|
Evaluate |
Recommend evaluation by a specialist |
|
|
Comment |
For your information |
Concern items are sorted by the types
listed above. Click
here for a glossary of building construction terms.
Table of Contents
Exterior
Porch
Detached
garage or carport
Bedroom/s
Roof
Plumbing
and laundry
Heating
and air conditioning
Electric
service
Kitchen/Interior
rooms
Water
heater
Attic
Crawl
space
General
information
Footing material: Masonry
Foundation material: Concrete block
Apparent wall structure: Wood frame
Wall covering: Metal, Asbestos-based
shingles
Driveway material: Poured in place
concrete
Sidewalk material: Poured in place
concrete
Exterior door material: Solid core
steel
|
|
1) One or more trip hazards were found in the
sidewalk due to cracks and/or settlement. Recommend having a qualified
paving contractor repair or replace sidewalk section(s) as necessary to
eliminate trip hazards.
|
||||
|
|
2) While I am not qualified to positively
identify the presence of asbestos, the exterior siding on this house does
appear to be a type of asbestos containing shingle. A test by a qualified
individual would have to be performed to make a positive identification.
|
||||
|
|
3) The perimeter grading slopes towards the
structure in one or more areas. This can result in water accumulating
around the structure's foundation, or in basements and crawl spaces if
they exist. Accumulated water is a conducive condition to wood destroying
insects and organisms. Wet soil may also cause the foundation to settle
and possibly fail over time. Recommend grading soil so it slopes down and
away from the structure with a slope of at least 5% (10% or better is
optimal) for at least 6 feet. |
||||
|
|
4) One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Recommend making repairs as necessary such as repairing or installing splash blocks or tie-ins to underground drain lines so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.
|
||||
|
|
5) One or more gutters are damaged. This can
result in water accumulating around the structure's foundation, or in
basements and crawl spaces if they exist. Accumulated water is a conducive
condition to wood destroying insects and organisms, and may also cause the
foundation to settle and possibly fail over time. Recommend having a
qualified contractor replace or repair gutters where necessary. |
||||
|
|
6) Moderate wood rot was viewed at the front
door threshold. Proper maintenance or replacement is required to prevent
further damage to this section of wood. Also note the small hole to the
left of the porch. This is a potential rodent entry point and should be
repaired.
|
||||
|
|
7) The exterior finish in some areas is
failing. Recommend having a qualified painting contractor prep (pressure
wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as
needed and as per standard building practices. |
||||
|
|
8) Siding is missing in some areas. This
should be replaced to prevent water entry and damage to the wall
structure. It appears, in this photo, as though the fascia is water
damaged. Other damage resulting from this defect was not visible during
the time of the inspection.
|
||||
|
|
9) One or more outside faucets were not
evaluated due to their being winterized with covers, and are excluded from
this inspection. |
||||
|
|
10) No outside outlets were seen on the
exterior of the house. At leas two outside outlets should be located on
your home. One on the front and one on the rear. They must be located
within 6'6" of grade level , be readily accessible, and be GROUND
FAULT CIRCUIT INTERRUPTER protected(GFCI). |
|
|
11) The front porch was covered by exterior
carpeting preventing a full view of its surface. The viewable area
appeared in general good condition. Minor damage was viewed at the bottom
right CMU mortar. |
|
|
12) The rear porch is in good condition. |
|
|
13) Metal window awnings appear in good
condition. |
|
|
14) Metal porch covers appear solid and in
good condition. |
Footing material: Poured
in place concrete
Foundation material: Poured in place
concrete
Apparent wall structure: Wood frame
Wall covering: Vinyl
Exterior door material: N/A
Roof inspection method: Viewed from
ground with binoculars
Roof type: Hipped
Roof covering: Asphalt or fiberglass
composition shingles
Estimated age of roof: Unknown
Gutter & downspout material: Aluminum
Roof ventilation: None visible
|
|
15) It appears as though electricity was
provided at one point but has been removed. This photo shows an abandoned
electrical entry point. A qualified electrical would have to be contacted
to determine whether or not this is a usable source of electricity.
|
||
|
|
16) There are no outlets provided in the
garage. Outlets should be installed with at least one being GFCI. |
||
|
|
17) Anchor bolts (photo 23), used to secure
the garage to the foundation, are improperly installed resulting in wall
movement (photo 24). A qualified building contractor should be contacted
to make necessary repairs. |
||
|
|
18) Moderate water damage was viewed at
several areas of the garage. This is caused by non water treated lumber
used for the construction. It appears as though this garage was
constructed by an individual not licensed in the building trades. I
recommend a qualified building contractor make the necessary
repairs/modifications. It would be wise to see if a permit was pulled for
the construction of this garage.
|
||
|
|
19) The garage vehicle door is damaged and
does not close all the way without considerable force. Recommend having a
qualified garage door contractor repair vehicle door(s) as necessary. |
||
|
|
20) Surface cracking was viewed throughout the
garage slab. The area cracking appears to be a secondary application used
to cover the original slab. |
||
|
|
21) Firewood is stored so that it's either in
contact with the structure or very close to it. The is a conducive
condition for wood destroying insects. Recommend storing firewood outdoors
in an open area, as far away from the house as practical, to keep away
insects. For more information visit http://ohioline.osu.edu/hyg-fact/2000/2065.html
|
|
|
22) Front bedroom widows fall when in the open
position. Double hung and single hung windows have spiral balances, block
& tackle balances, counter balances, jamb liners or sash ropes on both
sides which serves as the mechanism that allows the windows to open and
close freely and to remain at any desire position. These mechanisms have
springs or cords that maybe broken or loose which could result from normal
wear and tear causing the windows not to stay up. Adjustment or
replacement of the mechanism maybe required to allow the windows to open
and close freely. Surface cracking was viewed throughout the garage slab.
The area cracking appears to be a secondary application used to cover the
original slab. |
||
|
|
23) Rear bedroom widows fall when in the open
position. Double hung and single hung windows have spiral balances, block
& tackle balances, counter balances, jamb liners or sash ropes on both
sides which serves as the mechanism that allows the windows to open and
close freely and to remain at any desire position. These mechanisms have
springs or cords that maybe broken or loose which could result from normal
wear and tear causing the windows not to stay up. Adjustment or
replacement of the mechanism maybe required to allow the windows to open
and close freely. Surface cracking was viewed throughout the garage slab.
The area cracking appears to be a secondary application used to cover the
original slab. |
||
|
|
24) Rear bedroom door and closet door do not
close properly. The door mechanisms do not work and should be replaced to
allow for proper function. |
||
|
|
25) When walking near the side window in the
rear bedroom, see photo, I could hear the ductwork under the house buckle.
After inspecting this area in the crawlspace, it appears as though the
ductwork installed moves a little with the flooring system. This is not a
major concern just a nuisance.
|
Roof inspection method: Viewed
from ground with binoculars
Roof type: Cross-hipped
Roof covering: Asphalt or fiberglass
composition shingles
Estimated age of roof: Unknown
Gutter & downspout material: Aluminum
Roof ventilation: Inadequate
|
|
26) The roof appears to be in good condition.
I recommend asking the seller when it was installed to get a general idea
when your next replacement will need to take place. |
|
|
27) The television antenna is mounted to the
chimney. This places stress on the chimney and is not a recommended method
of installation. |
Location of main water shut-off valve: Laundry
Location of main water meter: Laundry
Location of main fuel shut-off: Rear of
home
Water service: Public
Service pipe material: Copper,
Galvanized steel
Supply pipe material: Copper,
Galvanized steel
Vent pipe material: Galvanized steel
Drain pipe material: Galvanized steel,
Copper
Waste pipe material: Cast iron, Copper
|
|
28) This leaking main waste line, located in
the crawl space, is an environmental hazard and should be repaired by a
licensed plumber. This may be a contributing factor in the presence of
moisture in the crawl space area.
|
||
|
|
29) Some, most, or all of the water supply
pipes in this structure are made of galvanized steel. Based on the age of
this structure, these pipes may be nearing or may have exceeded their
estimated useful life of 40 and 60 years. Internal corrosion and rust can
reduce the inside diameter of these pipes over time, resulting in reduced
flow and eventually, leaks. The inspector performed a "functional
flow test" during the inspection where multiple fixtures were run
simultaneously, and found the flow to be adequate. For example, the shower
flow didn't decrease substantially while the toilet was flushed. Despite
this, and given their apparent age, these pipes may need replacing at any
time. |
||
|
|
30) A plumbing leak was viewed at the plumbing
closet, located in the rear bedroom. The circle in this photo shows the
active leak. Note also the damage to the sheet rock as a result of past or
present water leaks.
|
||
|
|
31) Improper main waste line was viewed in the
crawlspace. A proper support should be installed to secure the waste line
and prevent damage form failure of current support. I recommend a
qualified plumber make necessary repairs/replacement.
|
||
|
|
32) While they were once an acceptable method
of plumbing trap, drum traps are no longer used as they do not provide a
proper water trap. This trap should be replaced by a licensed plumber for
updating.
|
Heating system energy source: Natural
gas
Heat system type: Forced air
A/C energy source: N/A
Distribution system: Sheet metal ducts
Brand & model: GSD-75-MHN 75,000
BTU
Location of filter(s): Top of Furnace
|
|
33) Because of the age and/or condition of
this furnace, recommend that a qualified heating and cooling technician
inspect the heat exchanger and perform a Carbon Monoxide test when it's
serviced. |
||
|
|
34) A significant gas leak was detected at the
drip leg on the furnace. I turned the gas off to this unit. I recommend a
qualified HVAC tech make necessary repairs to this gas line to prevent
damage to the property and other persons.
|
||
|
|
35) The estimated useful life for forced air
furnaces is 15 to 20 years. This furnace appears to be approaching this
age and may need replacing at any time. |
||
|
|
36) Last service date of this system is more
than one year ago or is unable to be determined. Recommend asking seller
when it was last serviced. If unable to determine or if more than one year
ago, recommend that this system be inspected, cleaned, serviced and
repaired if necessary by a qualified heating and cooling technician.
Recommend that this servicing be made annually in the future. |
||
|
|
37) This system is equipped with throw-away
filter(s). They appear to be dirty. Recommend replacing filter(s) now and
every 2 months in the future if the thermostat's fan position is set to
"Auto", or monthly if it's set to "On". |
Primary service type: Overhead
Primary service overload protection type: Fuses
Service amperage (amps): 100
Service voltage (volts): 120-240
Location of main service panel: Laundry
Location of main disconnect: Breaker at
top of main panel
Service conductor material: Aluminum,
Copper
Main disconnect rating (amps): 60
Branch circuit wiring type: Non-metallic
sheathed
Solid strand aluminum branch circuit wiring present: Can't
verify
Smoke detectors present: No
|
|
38) Service drop wires are less than 10 feet
above ground or walkways. Recommend having a qualified, licensed
electrician and/or the utility company evaluate and repair.
|
||
|
|
39) One or more circuit breakers are
"double tapped", where 2 or more wires are clamped in a circuit
breaker terminal, and the circuit breaker is only designed for 1 wire.
This is a safety hazard since wires may loosen and cause arcing, sparking
and fires. Recommend having a qualified, licensed electrician evaluate and
repair.
|
||
|
|
40) This panel is outdated and should be
replaced to meet current standards. A qualified electrical will have to
make the necessary changes to the main panel. |
||
|
|
41) No smoke detectors are visible. Recommend
installing smoke detectors as necessary so a functioning one exists in
each hallway leading to bedrooms, and in each bedroom. For more
information on smoke detectors visit http://www.cpsc.gov/cpscpub/pubs/5077.html
|
||
|
|
42) One or more smoke detectors is damaged or
missing, and an insufficient number of smoke detectors are installed.
Recommend replacing inoperable smoke detectors as necessary, and
installing additional smoke detectors as necessary so a functioning one
exists in each hallway leading to bedrooms, and in each bedroom. For more
information on smoke detectors visit http://www.cpsc.gov/cpscpub/pubs/5077.html
|
||
|
|
43) Inadequate
clearance exists to the main service panel. Recommend having a qualified,
licensed electrician make modifications as necessary so: · An
area 3" wide by 3' deep exists in front of the panel · The
panel is at least 5 1/2 feet above the floor · There's
at least 6'3" of headroom · The
wall below the panel is clear to the floor |
||
|
|
44) One or more bushings are missing from
where wires enter holes in the main service panel. This is a safety hazard
since the wiring insulation can be cut or abraded on the metal edge of the
hole(s). Recommend having a qualified, licensed electrician install
bushings where missing.
|
||
|
|
45) Ground and neutral wires should be
isolated under their own screw and separate bus bar. This photo shows both
ground and neutral conductors under the same screw and on the same bus
bar. This is common practice in older outdated panels.
|
||
|
|
46) Improperly secured conductors were viewed
in the attic area. To prevent damage to these conductors, they should be
properly secured by a licensed electrician.
|
||
|
|
47) This photo shows a two prong ungrounded
outlet located close to the shower area. This should be removed by a
licensed electrical to prevent possible electrical shock.
|
||
|
|
48) The conductors in this photo are located
in the rear bedroom closet. This conductor should be installed behind the
wall to prevent damage to it and to prevent possible electrical shock to
persons coming in contact with damaged sheathing.
|
||
|
|
49) One or more screws are missing from the
main service panel cover. Recommend replacing missing screws. |
||